MOX gas sensor elements of GGS series - Types and detectable gases

For more entries please swipe to left.

Gas \ Type of MOX-gas sensor GGS
1000
series
GGS
2000
series
GGS
3000
series
GGS
4000
series
GGS
5000
series
GGS
6000
series
GGS
7000
series
GGS
8000
series
GGS
9000
series
GGS
10000
series
UST Triplesensor® type 3A4P
Hydrocarbons (CXHY) according to specification of gas-sensitive layers
Hydrogen (H2)
Carbon monoxide (CO)
Alcohols (CXHYOH)
Nitrogen dioxide (NO2)
Nitrogen monoxide (NO)
Ozone (O3)
Ammonia (NH3)
Sulfur dioxide (SO2)
Refrigerants (R134a u.a.)
Volatile Organic Compounds (VOCs)
Datasheet


For more entries please swipe to left.

 

Our MOX gas sensor elements will be pre-aged and selected regarding sensitivity and basic resistance RS0 of the sensitive layer. Physical and chemical limitations relating to the influence of basic resistance and sensitivity apply.
To select the most suitable sensor for a given application the following criteria apply:

  • Type of sensor / type of gas sensitive layer
  • Sensor design / dimensions / case 
  • Classes of heater resistance
  • Type/s of gas/es to be measured
  • Accuracy requirements
  • Ambient media and conditions.

ORDER SCHEME / TYPE CODE

Example: GGS 1430 T

Sensor element in a 4-Pin-TO39-Case with T-cap (stainless steel) - www.umweltsensortechnik.de
 
GGS Type of sensor elementSingle gas sensor element
1Sensor/ layer typeGGS 1000 - Universal sensor for various applications, especially usable for leak detection of combustible gases.
4Sensor chip size (L x W)2,0 mm x 2,3 mm
3Resistance RH0 of Platinum heater at 0°C10 Ω ± 0,5 Ω
0Class of accuracyRS0 = ± 75%, RS/RS0 = ± 30%
TSensor case 4-Pin-TO39-Case with T-cap (stainless steel)

Please swipe to left.


Detailed options:

Type of sensor element GGS1430T
GGSSingle gas sensor element
DGSDouble gas sensor element

Sensor/ layer typeGGS1430T
1GGS 1000Universal sensor for various applications, especially usable for leak detection of combustible gases.

2GGS 2000Sensor with a high sensitivity to CO (carbon monoxide), H2 (hydrogen) and C2H5OH (ethanol), low cross sensitivity to CH4 (methane).

3GGS 3000Sensor for the detection of hydrocarbonates, optimal for C1-8-hydrocarbonates, especially usable for stationary LEL-monitoring (LEL... Lower Explosive Limit).

4GGS 4000Sensor for NH3 (ammonia), low cross sensitivity to CH4 (methane), CO (carbon monoxide) and H2 (hydrogen).

5GGS 5000Sensor especially sensitive to NO2 (nitrogen dioxide) and O3 (ozone).

6GGS 6000Sensor for the detection of H2 (hydrogen), low cross sensitivity to CH4 (methane), CO (carbon monoxid) and alcohol.

7GGS 7000Sensor for the detection of NO (nitrogen monoxide).

8GGS 8000Sensor for the detection of C2H5OH (ethanol), low cross sensitivity to CH4 (methane), CO (carbon monoxide) and H2 (hydrogen).

9GGS 9000Sensor for R134a and other refrigerants.

10GGS 10000Sensor for the detection of selected VOCs (air components) in the trace range, usable e.g. for air quality monitoring.

Sensor chip size (LxW)GGS1430T
33,0 mm x 3,0 mm
42,0 mm x 2,3 mm
51,5 mm x 1,5 mm

Resistance Platinum heater RH0 at 0°CGGS1430T
030 Ω ± 0,5 Ω
310 Ω ± 0,5 Ω
716 Ω ± 1 Ω

Class of accuracy GGS1430T
0RS0 = ± 75%, RS/RS0 = ± 30%
(RS0... basic resistance of sensitive layer, RS… resistance of sensitive layer)

Sensor caseGGS1430T
T4-Pin-TO39-Case with T-cap (stainless steel)4-Pin-TO39-Case with T-cap (stainless steel) - www.umweltsensortechnik.de

2T4-Pin-TO39-Case with 2T-cap (stainless steel) and glass filter4-Pin-TO39-Case with 2T-cap (stainless steel) and glass filter - www.umweltsensortechnik.de

Subject to alterations for this information and technological changes.

IMPORTANT REMARKS

Any contamination of the sensor must be avoided. The application, transport and storage environment has to be free of any contamination, particularly protected against chemical substances, e.g. silicones.

In particular directly contact with substances containing, silicones, sulfurous substances or non-desorbing components or contaminations (e.g. smoke, fumes, oils, greases or evaporating liquids) may cause damaging the sensor or to changes in the sensor resistance and/or in the sensor characteristics.

DOWNLOAD

TRADEMARK(S)

UST Triplesensor® is a registrated trademark of UST Umweltsensortechnik GmbH, Dieselstr. 2 und 4, 99331 Geratal OT Geschwenda, Germany.